3-Stage Switch for 3-Phase Electric Infrared Heaters S123
3-Stage Switch for 3-Phase Electric Infrared Heaters S123
Availability for pickup could not be loaded
3-stage switch for 3-phase electric infrared heaters, in surface-mounted enclosure IP65
This step switch connects three circuits one after another in three stages. It comes ready for connection in an insulated surface-mounted enclosure and is suitable for loads that need to be switched in stages. Typical examples are electric heaters with several heating elements, infrared heaters, fans or lighting groups.
Switching sequence
- Position 0: off, all contacts open
- Position 1: one contact closed (1 of 3)
- Position 2: two contacts closed (2 of 3)
- Position 3: all three contacts closed (3 of 3)
When connected to L1, L2 and L3, one, two or three phases can be switched on. This allows, for example, a three-phase unit with three heating elements to run at one third, two thirds or full output.
Features
- 3 contacts in 2 contact units
- Detented switch positions with 45° switching angle
- Robust surface-mounted enclosure with IP65 protection, dust-tight and protected against water jets
- Enclosure with knockouts for M20 cable glands
- Screw terminals
- Black thumb grip, front plate with position indication 0, 1, 2, 3
- Wall mounting
Technical data
| Design | Step switch with off position, enclosed |
| Switch positions | 4 (0, 1, 2, 3) |
| Number of contacts | 3 |
| Rated uninterrupted current Iu | 20 A |
| Rated operational voltage Ue | up to 690 V AC |
| Degree of protection | IP65 |
| Ambient temperature (enclosed) | -25 °C to +40 °C |
| Conductor cross-section | 1 x or 2 x 1.0 to 2.5 mm² (solid), 0.75 to 1.5 mm² (stranded with ferrule) |
| Terminal tightening torque | 1.0 Nm |
| Dimensions (W x H x D) | approx. 80 x 137 x 102 mm |
| Standards | IEC/EN 60947-3, IEC/EN 60204, VDE 0660 |
Tip: For single-phase 230 V infrared heaters with a Schuko plug, we recommend our socket switch IP44. It simply plugs in between the socket and the heater, without any electrical installation.
Note: Connection and installation by a qualified electrician only. Switch and supply cable must be rated for the power and fuse protection of the connected load.